Search results for "Femoral Artery"
showing 10 items of 57 documents
Spontaneous echo contrast caused by platelet and leukocyte aggregates?
2001
Background and Purpose —Spontaneous echocardiographic contrast (SEC) is correlated to clinical thromboembolic events. We sought to determine the origin of SEC by utilizing direct analysis of left atrial blood. Methods —We examined the blood of 13 patients with and 19 without SEC. Blood samples were taken from the femoral vein and artery and from the right and left atria after transseptal puncture. Samples were incubated with fluorescence-labeled antibodies directed against the platelet (CD41a-PE, CD42b-PE, and CD62p-FITC) and leukocyte membrane epitopes (CD45-APC and CD14-FITC). The expressed epitopes were analyzed by dual laser flow cytometry immediately after blood withdrawal. Results —I…
Relationship between albumin excretion rate and aortic stiffness in untreated essential hypertensive patients
2004
. Objectives. To evaluate, in a group of nondiabetic essential hypertensive patients with normal renal function, the relationship between albumin excretion rate (AER) and carotid-femoral pulse wave velocity (PWV), as an index of aortic stiffness. Design. Cross-sectional study. Setting. Outpatient hypertension clinic. Subjects. Seventy patients with mild-to-moderate essential hypertension, aged 42 ± 8 years, never pharmacologically treated. All subjects underwent routine laboratory tests, 24-h ambulatory blood pressure (BP) monitoring, measurement of carotid-femoral PWV, by means of a computerized method, and AER. Results. Microalbuminuric patients (AER ≥ 20 μg min−1; n = 19), when comp…
Two-stage multi-Gaussian fitting of conduit artery photoplethysmography waveform during induced unilateral hemodynamic events.
2014
Photoplethysmography (PPG) is an optical technique with high diagnostic potential, yet clinical applications remain underdeveloped. Standardization of signal recording and quantification of waveform are essential prerequisites for broader clinical use. The aim of this study was to utilize a two-stage multi-Gaussian fitting technique in order to examine the parameters of conduit artery PPG waveform recorded during increasing the unilateral regional vascular resistance (RVR). This study was conducted on 14 young and healthy volunteers; various external compressions (ECs) were performed by inflating a tight cuff at 0, 40, 80, and 200 mmHg, while registering femoral PPG (wavelength 880 nm), dia…
Symptomatic Deep Femoral Artery Pseudoaneurysm Endovascular Exclusion. Case Report and Literature Review.
2017
Deep femoral artery pseudoaneurysms (DFAPs) are rare and generally occur after penetrating trauma or surgical procedures. A 36-year-old obese man presented with pain in correspondence of the anterior-lateral thigh after 6 months from gunshot wound. Duplex and computed tomography (CT) showed a bilobed right DFAP (maximal diameter 12.9 cm). The patient was managed urgently, under local anesthesia, by placement in the distal DFA of a Viabahn 8 Ã 100-mm stent graft (W L Gore & Associates, Inc). The postoperative course was uneventful, and the 24-month CT showed regular stent-graft patency and 20-mm DFAP shrinkage. The literature review reported 8 cases of DFAPs; of these 6 were managed by endo…
Pulse pressure amplification and its determinants
2015
Background. Pulse pressure (PP) amplification expressed as the peripheral-to-central PP ratio has gained importance in the assessment of cardiovascular phenotypes and cardiovascular risk. The aim of the present study was to assess the relationship between PP amplification, large vessel parameters and peripheral blood pressure (BP) to gain insights into the amplification phenomenon. Methods. Peripheral BP, central BP and carotid-femoral pulse wave velocity (cfPWV) were assessed using the OMRON M6, SphygmoCor and Complior devices, respectively, in 741 adults attending the hypertension outpatient clinic. Analysis of covariance, partial correlations and multiple linear regression models were pe…
One-year results from the DETOUR I trial of the PQ Bypass DETOUR System for percutaneous femoropopliteal bypass
2019
The objective of this study was to evaluate the 1-year safety and effectiveness outcomes associated with the PQ Bypass DETOUR System (PQ Bypass, Milpitas, Calif) for the percutaneous bypass of long-segment femoropopliteal occlusive disease.This prospective, single-arm, multicenter trial enrolled patients with long-segment femoropopliteal arterial disease. The DETOUR System percutaneously deploys modular stent grafts to bypass femoropopliteal lesions through a transvenous route. Eligible patients included those with TransAtlantic Inter-Society Consensus C and D lesions100 mm in length. The primary safety end point was the major adverse event (MAE) rate through 1 month, defined as the composi…
Influence of the metabolic syndrome on aortic stiffness in never treated hypertensive patients
2004
Summary Background and aim Metabolic syndrome (MS) carries an increased risk for cardiovascular events and there is a growing awareness that large artery stiffening is a powerful predictor of cardiovascular morbidity and mortality. Little is known about the relationship of MS with aortic stiffness. The aim of our study was to analyze, in patients with essential hypertension, the influence of MS, defined according to the criteria proposed by the Third Report of the National Cholesterol Education Program Expert Panel on Detection, Evaluation, and Treatment of High Blood Cholesterol in Adults (NCEP-ATP III), on carotid–femoral pulse wave velocity (PWV), a measure of aortic stiffness. Methods N…
Successful use of impella CP through femoral access in a patient with bilateral iliac and aortic endoprosthesis in the setting of cardiogenic shock
2019
We report the case of a 67-year-old male, with previous history of severe peripheral vascular disease (abdominal aorta aneurism and bilateral iliac stenosis) requiring the implantation of 3 endoprostheses 7 months ago (Figure 1(A)), and previous myocardial infarction 10 years ago. The left ventricular ejection fraction (LVEF) was preserved at last control (58%). The patient was referred for acute coronary syndrome complicated with pulmonary oedema and cardiogenic shock. Echocardiography showed a severe impairment of LVEF (18%) and the patient was transferred to cathlab for emergency percutaneous coronary intervention (PCI). Coronary angiography via right femoral 7Fr access showed a chronic …
�ber den Einflu� vegetativ wirksamer Pharmaka auf die Folgen der Injektion von Thiopental in die Arteria femoralis der Ratte
1962
An 150 Ratten wurde der Einflus vegetativ wirksamer Pharmaka (Reserpin, Guanethidin, Chlorisondamin, Dibenamin, Atropin, Hydroxyphenylaminoathanol) auf die Folgen einer Injektion von Thiopental in die Femoralarterie untersucht. Keine der gepruften Substanzen verminderte die durch Thiopental verursachten lokalen Schadigungen.
The automated assesment of artery hemodynamic parameters from ultrasound video
2012
The custom designed video processing software for analysis of B-mode and Doppler-mode ultrasound video has been proposed in this work. The software allows adjusting user-defined thresholds and tolerance levels to enhance contour detection in noisy and artifacted ultrasound images. The developed software is able to evaluate 16 hemodynamic parameters (artery diameter, pulse rate and flow velocity related parameters) in each cardiac cycle. The measurements were performed intermittently recording artery diameter (B-mode) and flow velocity (Doppler-mode). Software has validated in femoral artery measurements. The hemodynamic parameters computed by software were consistent with those obtained by …